CJX2-D115-620N Series Reversing AC Contactor

CJX2-D115N
Product specifications:
The CJX2 series AC contactors (hereinafter referred to as contactors) are primarily used in circuits operating at 50Hz (or 60Hz) AC, with a rated operating voltage up to 690V and a rated operating current up to 95A in the AC-3, 400(380)V utilization category. They are used for remote circuit connection and disconnection, frequent starting, and control of AC motors. They can also be combined with appropriate thermal relays to form electromagnetic starters to protect circuits from potential operational overloads.
Compliant with standards: GB/T 14048.4, IEC/EN 60947-4-1.
Rated current: 9~800A
Control mode: AC

1.Application

CJX2-N series reversing contactor is suitable for using in the circuits of AC 50Hz or 60HZ, the ratedinsulation voltage 690V, rated current up to 800A, convertible controling the motor, it can avoidshort circuit when reversing. Combined with the thermal overload relay, it can protect overloadcircuit.

This product conforms to GB14048.4、1EC60947-4-1 standard.

 

2.Model And Meaning

CJ X 2 -□□□N□

CJ :  AC contactor
X :  Miniature
2 :  Design sequence No.
□ :  Rated operational current ( AC-3 380V )
□ :  Number of N/C auxiliary contacts
□ :  Number of N/C auxiliary contacts
N : Mechanical interlock
□ : Istallation method: S: Horizontal installation C:Vertical installation

 

3.Normal Running And Installation Conditions

3.1 Ambient air temperature: -5℃~ +40℃, the average value should not exceed +35℃ within 24hours.
3.2 Elevation: at most 2000m.
3.3 Atmospheric conditions: When the temperature at 40, the relative humidity of atomsphere shouldbe at the most 50%. When at relatively low temperatures, it could have higher relative humidityMonthly maximum relative humidity could be not more than 90%. Special measures should betaken due to occurrence of dews.
3.4 Class of pollution: Class 3
3.5 Installation category:Ⅲ
3.6 lnstallation conditions: Degree of inclination between fitting surface and vertical surface should not exceed
3.7 lmpact shock: Product should be installed and used in the place where often shakes and impacts.

 

4.Technical Parameter

● Tabel 1

ltem / Parameter / Model CJX2-09N CJX2-12N CJX2-18N CJX2-25N CJX2-32N CJX2-40N CJX2-50N CJX2-65N CJX2-80N CJX2-95N
Rated operational 380V AC-3 current(A) 9 12 18 25 32 40 50 65 80 95
Power of control-
lable 3-phase squirrel-cage motor(kW) AC-3
220V 2.2 3 4 5.5 7.5 11 15 18.5 22 25
380V 4 5.5 7.5 11 15 18.5 22 30 37 45
660V 5.5 7.5 10 15 18.5 30 33 37 45 55
Unit weight(Kg) 3P 0.72 0.72 0.72 1.11 1.18 2.49 2.52 2.55 2.96 2.97

 

● Tabel 2

ltem / Parameter / Model CJX2-115N CJX2-150N CJX2-170N CJX2-205N CJX2-245N CJX2-300N CJX2-410N CJX2-475N CJX2-620N
Rated operational 380V AC-3 current(A) 115 150 170 205 245 300 410 475 620
Power of control-
lable 3-phase squirrel-cage motor(kW) AC-3
220V 30 40 55 63 75 100 110 147 200
380V 55 75 85 90 110 160 200 250 335
660V 80 90 100 110 129 220 280 330 450
Unit weight(Kg) 3P 4.32 4.32 4.32 9.9 10.2 18.4 18.7 24 38.8

 

● Tabel 3

ltem / Parameter / Model CJX2-F115N CJX2-F150N CJX2-F185N CJX2-F225N CJX2-F265N CJX2-F330N CJX2-F400N CJX2-F500N CJX2-F630N CJX2-F800N
Rated operational 380V AC-3 current(A) 115 150 185 225 265 330 400 500 630 800
Power of control-
lable 3-phase squirrel-cage motor(kW) AC-3
220V 30 40 55 63 75 100 110 147 200 250
380V 55 75 90 110 132 160 200 250 335 450
660V 80 100 110 129 160 220 280 330 450 470
Unit weight(Kg) 3P 7.7 8 9.9 10.2 15.3 18.4 18.7 24 38.8 44.2
4P 9.4 10 10.1 12.9 18.8 22.3 22.9 29.6 47.6

 

5.Overall And Mounting Dimensions

Photo 1 CJX2-09N~32N(Horizontal installation)

Photo 2 CJX2-40N~95N(Horizontal installation)

Photo 3 CJX2-115N~170N(Horizontal installation)

Photo 4 CJX2-F115N~F330N,CJX2-205N~300N(Horizontal installation)

Photo 5 CJX2-F400N~F500N,CJX2-410N~475N(Horizontal installation)

Photo 6 CJX2-F630N~F800N,CJX2-620N(Horizontal installation)

Photo 7 CJX2-F115N~F330N(Vertical installation)

Photo 8 CJX2-F400N~F500N(Vertical installation)

Photo 9 CJX2-F630N~F800N(Vertical installation)

Photo 10 CX2-F780N(Vertical installation)

 

CJX2-09N~170N(Horizontal installation)  ● Tabel 4 (Unit: mm)

Contactor Model Amax Bmax Cmax h ø
CJX2-09N~12N 81 106 85 95 4.5
CJX2-18N 81 106 87 95 4.5
CJX2-25N 94 129 100 112 4.5
CJX2-32N 96 129 103 112 4.5
CJX2-40N~65N 129 165 116 50 90 6.5
CJX2-80N~95N 129 185 127 57 96 6.5
CJX2-115N~170N 162 268 133 242/256 6.5

 

CJX2-F115N~F330N,CJX2-205N~300N(Horizontal installation)  ● Tabel 5 (Unit: mm)

Contactor  Model a P P1 Q1 S Ø f b b1 M C L G J H 1 Y X1
≤500V >500V
CJX2-F115 346 37 78 60 15 M6 109 162 137 147 171 107 80 72 120/106 6.5 57 10 15
CJX2-F1154 420 37 78 60 15 M6 109 162 137 147 171 107 80 109 120/106 6.5 75.5 10 15
CJX2-F150 346 40 72 57.5 20 M8 109 170 137 150 171 107 80 72 120/106 6.5 57 10 15
CJX2-F1504 420 40 72 55.5 20 M8 109 170 137 150 171 107 80 109 120/106 6.5 75.5 10 15
CJX2-F185,205 357 40 78 59.5 20 M8 117 174 137 154 181 113.5 80 78 120/106 6.5 59.5 10 15
CJX2-F1854 437 40 78 59.5 20 M8 117 174 137 154 181 113.5 80 118 120/106 6.5 79.5 10 15
CJX2-F225,245 357 48 62 51.5 25 M10 117 197 137 175 181 113.5 80 78 120/106 6.5 59.5 10 15
CJX2-F2254 437 48 54 47.5 25 M10 117 197 137 175 181 113.5 80 118 120/106 6.5 79.5 10 15
CJX2-F265 424 48 99 66.5 25 M10 143 203 145 178 213 141 96 109 120/106 6.5 61.5 10 15
CJX2-F2654 520 48 99 66.5 25 M10 143 203 145 178 213 141 96 157 120/106 6.5 85.5 10 15
CJX2-F330,300 445 48 105 74 25 M10 143 206 145 181 219 145 96 122 120/106 6.5 65.5 10 15
CJX2-F3304 541 48 105 74 25 M10 143 206 145 181 219 145 96 170 120/106 6.5 89.5 10 15

 

CJX2-F400N~F500N,CJX2-410N~475N(Horizontal installation)  ● Tabel 6 (Unit: mm)

Contactor  Model a P P1 Q1 S Ø f b b1 M c L G G1 J H Ø1 Y X1
≤500V >500V
CJX2-F400,410 445 48 105 74 25 M10 151 206 209 181 219 145 80 170 156 170/170 8.5 19.5 15 20
CJX2-F4004 541 48 105 74 25 M10 151 206 209 181 219 145 80 170 156 170/170 8.5 67.5 15 20
CJX2-F500,475 485 55 111 77 30 M10 151 206 209 181 219 145 80 170 156 170/170 8.5 39.5 15 20
CJX2-F5004 595 55 111 77 30 M10 151 206 209 181 219 145 80 170 156 170/170 8.5 34.5 15 20

 

CJX2-F630N~F800N,CJX2-620N(Horizontal installation)  ● Tabel 7 (Unit: mm)

Contactor Model a P P1 Q1 S ø f b b1 M C L G J H Ø1 Y X1
≤500V >500V
CJX2-F630,620 636 80 138 89 40 M12 210 304 280 264 255 155 180(100/195) 139 180/190 10.5 68.5 20 30
CJX2-F6304 796 80 138 89 40 M12 210 304 280 264 255 155 240(150/275) 139 180/190 10.5 68.5 20 30
CJX2-F800 636 80 138 89 40 M12 210 304 280 264 255 155 180(100/195) 139 180/190 10.5 68.5 20 30

 

CJX2-F115N~F330N(Verticalinstallation)  ● Tabel 8 (Unit: mm)

Contactor Model a P Q1 Q S 0 f b P1 M C L G H J Ø1 Z Y X1
≤500V >500V
CJX2-F115 184 37 60 50 15 M6 109 357-472 48-163 147 171 107 80 120 80-195 6.5 47 57 10 15
CJX2-F1154 221 37 60 50 15 M6 109 357-472 48-163 147 171 107 80 120 80-195 6.5 65.5 75.5 10 15
CJX2-F150 84 40 57 47 20 M8 109 365-480 45-160 150 171 107 80 120 80-195 6.5 47 57 10 15
CJX2-F1504 221 40 55.5 45.5 20 M8 109 365-480 45-160 150 171 107 80 120 80-195 6.5 655 75.5 10 15
CJX2-F185 192 40 59.5 52.5 20 M8 117 389-484 61-156 154 181 113.5 80 120 100-195 6.5 52.5 59.5 10 15
CJX2-F1854 232 40 59.5 52.5 20 M8 117 389-484 41-156 154 181 13.5 80 120 100-195 6.5 72.5 79.5 10 15
CJX2-F225 192 48 51.5 44.5 25 M10 117 412-507 43-138 172 181 113.5 80 120 100-195 6.5 52.5 59.5 10 15
CJX2-F2254 232 48 47.5 40.5 25 M10 117 412-507 43-138 172 181 1135 80 120 100-195 6,5 725 79.5 10 15
CJX2-F265 226 48 66.5 63.5 25 M10 143 448-583 47-202 178 213 141 96 120 130-265 6,5 685 61.5 10 15
CJX2-F2654 274 48 66.5 63.5 25 M10 143 448-583 47-202 178 213 141 96 120 130-265 6.5 92.5 85.5 10 15
CJX2-F330 240 48 74 70 25 M10 143 481-586 94-199 181 219 145 96 120 160-265 6,5 78.5 65.5 10 15
CJX2-F3304 288 48 74 70 25 M10 143 481-586 94-199 181 219 145 96 120 160-265 6.5 102.5 89.5 10 15

 

CJX2-F400N~F500N(Vertical installation)  ● Tabel 9 (Unit: mm)

Contactor  Model a P Q1 Q S Ø f b P1 M c L G G1 H J Ø1 z Y X1
≤500V >500V
CJX2-F400 240 48 74 70 25 M10 151 481-586 94-199 181 219 145 80 170 180 156 8.5 50.5 19.5 15 20
CJX2-F4004 288 48 74 70 25 M10 151 481-586 94-199 181 219 145 80 170 180 156 8.5 50.5 67.5 15 20
CJX2-F500 261 55 77 74 30 M10 169 533-618 87-172 208 232 146 80 170 180 156 8.5 51.5 39.5 15 20
CJX2-F5004 316 55 77 74 30 M10 169 533-618 87-172 208 232 146 140 230 180 156 8.5 51.5 34.5 15 20

 

CJX2-F630N~F800N(Vertical installation)  ● Tabel 10 (Unit: mm)

Contactor  Model a P Q1 Q S Ø f b P1 M c L G H J Ø1 Z Y X1
≤500V >500V
CJX2-F630 309 80 89 60 40 M12 210 669-684 101-116 264 255 155 180(100/195) 190 180-195 10.5 60.5 68.5 20 30
CJX2-F6304 389 80 89 60 40 M12 210 669-684 106-116 264 255 155 240(150/275) 190 180-195 10.5 60.5 68.5 20 30
CJX2-F800 389 80 89 60 40 M12 210 669-684 106-116 264 255 155 180(100/195) 190 180-195 10.5 60.5 68.5 20 30

 

CJX2-F780N(Vertical installation)  ● Tabel 11 (Unit: mm)

Contactor  Model a P Q1 Q S Ø f b P1 M H c L G G1 H Ø1 Z Y X1
≤500V >500V
CJX2-F780 704 160 192 192 60 M12 201 439 81-101 400-438 202 225 165 240 180 10.5 91 133 20 30
CJX2-F7804 864 160 192 192 60 M12 201 439 81-101 400-438 202 225 165 240 190 180 10.5 91 133 20 30

 

6.Ordering Instructions

When placing an order, you should point out the below:

Product name and model, rated operational voltage and frequency of coil, order quantity

Ordering example: Reversing Contactor CJX2-40N AC 220V 50Hz 60PCS.

 

Hot Products
Beautiful exterior design, industrial-grade interior materials, 30 years of rich production experience.